Type UKV-J/JKV Electronic Expansion Valves for CO₂ Refrigerant
Features
- Maximum operating pressure differential: 10 Mpa
- Small, lightweight design
- CV Value Range: 0.015–0.49
- Product lineup includes a variety of diameter options.
- UL certified products also available (excluding JKV).
Applications
Heat pump type hot water supplies, product display cases
Common Specifications
Maximum operating pressure: 15 MPa
Fluid temperature range: -30 to 70℃
*Products compatible with -50℃ also available. (UKV-J)
Operating ambient temperature range: -30 to 70℃
Excitation method: 1-2 phase excitation, unipolar stepper motor
Click below for inquiries regarding Type UKV-J/JKV Electronic Expansion Valves for CO₂ Refrigerant
Expansion Valves
- Type UKV Electronic Expansion Valves
- Type LKV Electronic Expansion Valves
- Type UKV-J/JKV Electronic Expansion Valves for CO₂ Refrigerant
- Type VKV Electronic Expansion Valves
- Type AKV Electronic Expansion Valves
- Type MKV Electronic Expansion Valves
- Type PKV Electronic Expansion Valves
- Type GKV Electronic Expansion Valves
- Type RKV Changeover Valves/Electronic Expansion Valves
- Type YNE EEV Controllers
- Type QCX/RCX Thermostatic Expansion Valves
- Type SCX Thermostatic Expansion Valves
- Type ATX Thermostatic Expansion Valves
- Type AEX Thermostatic Expansion Valves
- Type ARX Thermostatic Expansion Valves (Small Capacity Type)
- Type CEX Constant Pressure Expansion Valves
- Type CTX Constant Pressure Expansion Valves
- Type CGX Constant Pressure Expansion Valves, Capacity Regulating Valves
- Type SPX Constant Pressure Expansion Valves, Capacity Regulating Valves
- Type HEX Manually Operated Expansion Valves