Type ULK Vortex Flow Sensors

Features

  • Highly precise and durable Karman vortex liquid flow meter with simple construction and no moving parts.
  • Designed for minimal pressure drop and stable measurement across a wide range of flow rates.
  • Available in large-diameter pipe fittings.
  • CE marking compliant products also available.

Applications

Semiconductors, LCD technology

Common Specifications

Power supply voltage: DC 12 to 24 V ± 10%
Maximum operating pressure: 1 MPa (20℃)
Fluid temperature range: 0 to 50℃
Operating ambient temperature range: -0 to 50℃
Output: 4 to 20 mA
Accuracy: ± 3% FS
Fluids: water, hot water, oil, seawater, and other fluids (fluids that do not damage body material)
Flow range: 4 to 550 L/min